Domestic relays
Filter layout:
|
| MPN | Article | Brand | In stock | Price | Discounts | Quantity | Description | Weight g. | Working voltage, V | Mounting type | Factory packaging | Working current, A | Number of windings | Polarization | Winding resistance, Ohm | Operating current no more | Maximum switching voltage | Winding supply current | Contact set |
|---|
|
Relay RMug RS4.523.419
#11636
|
23866 | СНГ | 14 шт |
70 грн.
|
Relay RMUG RS4.523.419 is hermetically sealed, single-stable, powered by direct current, designed for switching electric circuits of direct and alternating current with a frequency of 50-400 Hz. | 135 | 60 | DIP | 2 pcs. | 1 | 1 | neutral | 5000 | — | 300v | Constant | 2 switches | |||
| 26054 | СНГ | 12 шт |
1,500 грн.
|
EMRV-27B-1 100-760 sec electric machine time relay is designed for switching electrical circuits with certain pre-set time delays and is used in industrial equipment for various purposes, to obtain time delays in industrial automation circuits and relay protection. Assigned resource 10,000 operations, with a time delay less than or equal to 27s; 75h - with time delay over 27s Main technical characteristics: DC supply voltage, V 27 ± 2.7 Supply voltage ripple amplitude, no more than 1% of the supply voltage value Current consumption at temperatures from 15°C to 70°C, A, not more than with the engine on 0.55, after the engine is stopped 0.40 Insulation resistance during the service life, kOhm, not less than 20. | 400 | — | — | 1 PC. | — | — | — | — | — | — | — | — | ||||
| 28072 | СНГ | 12 шт |
400 грн.
|
Indicating relays of the REU-11 series are designed to signal an emergency condition in the circuit. | 140 | 24 | Screw | 20pcs | — | 1 | — | 400 | — | — | Constant | 2 short circuit | ||||
| 26053 | СНГ | 10 шт |
1,500 грн.
|
EMRV-27B-1 5-20 sec electric machine time relay is designed for switching electrical circuits with certain pre-set time delays and is used in industrial equipment for various purposes, to obtain time delays in industrial automation circuits and relay protection. Assigned resource 10,000 operations, with a time delay less than or equal to 27s; 75h - with time delay over 27s Main technical characteristics: DC supply voltage, V 27 ± 2.7 Supply voltage ripple amplitude, no more than 1% of the supply voltage value Current consumption at temperatures from 15°C to 70°C, A, not more than with the engine on 0.55, after the engine is stopped 0.40 Insulation resistance during the service life, kOhm, not less than 20. | 400 | — | — | 1 PC. | — | — | — | — | — | — | — | — | ||||
| 27698 | СНГ | 10 шт |
25 грн.
|
4.5 | 5 | DIP | 10 pieces. | 0.5 | 1 | neutral | 67 | — | 36v | AC/DC | 1 switch | |||||
| 27700 | СНГ | 10 шт |
30 грн.
|
4.5 | 5 | DIP | 10 pieces. | 0.5 | 1 | neutral | 67 | — | 36v | AC/DC | 1 switch | |||||
| 28073 | СНГ | 8 шт |
400 грн.
|
Indicating relays of the REU-11 series are designed to signal an emergency condition in the circuit. | 160 | — | Screw | 20pcs | 0.16 | 1 | — | — | — | — | Constant | 2 short circuit | ||||
| 28144 | СНГ | 8 шт |
80 грн.
|
Relay RPS42B RS4.520.720-03 electromagnetic low-current low-frequency, polarized, bi-stable, two-position, with two changeover contacts. Designed for switching electrical circuits of direct and alternating current with a frequency of up to 10,000 Hz. RPS42 relays are used for operation as part of electrical (electronic) switching control circuits in equipment for general and special purposes. They are manufactured in two designs: - RPS42A - without elbows; - RPS42B - with elbows. Case type - metal , sealed. | 35 | 27 | DIP | 8pcs | 5 | 2 | polarized | 400 | — | 220v | — | 2 switches | ||||
|
Relay RES32 RF4.500.345 60V
#14954
|
27170 | СНГ | 5 шт |
60 грн.
|
Relay RES32 RF4.500.345 dust-splash-proof, two-position, single-stable, with four changeover contacts. designed for switching electrical circuits of direct and alternating current Technical characteristics of the relay RES32 RF4.500.345: • Winding resistance, Ohm ...... 2380-3080; • Operate current, mA ...... 11; • Release current, mA ...... 2; • Operating voltage, V ...... 54-66; • Insulation resistance between current-carrying elements and case: - in normal climatic conditions ...... not less than 100 MOhm; - in conditions of high humidity ...... not less than 10 MOhm; - at maximum temperature ...... not less than 20 MΩ; • Dielectric strength of insulation between current-carrying elements, current-carrying elements and housing ...... not less than 500 V; • Response time ...... no more than 15 ms; • Release time ...... no more than 8 ms. | 34 | 60 | DIP | 10 pieces. | 0.3 | 1 | neutral | 2700 | — | 500v | Constant | 4 switches | |||
| 27697 | СНГ | 5 шт |
25 грн.
|
4.5 | 6 | DIP | 10 pieces. | 0.5 | 1 | neutral | 95 | — | 36v | AC/DC | 1 switch | |||||
| 23470 | СНГ | 4 шт |
48 грн.
|
Low power solid-state optoelectronic relays. | 0.5 | — | DIP | 100 pieces. | — | — | — | — | — | — | — | — | ||||
| 27169 | СНГ | 3 шт |
60 грн.
|
RES-22 RF4.523.023-06.02 sheathed, two-position, single-stable, with four switching contacts of a DC relay, designed for switching DC and AC electrical circuits with a frequency of 50 ... 1000 Hz. Technical characteristics of the relay RES-22 RF4.523.023-06.02: • Winding resistance, Ohm ...... 2250-2875; • Operate current, mA ...... 10.5; • Release current, mA ...... 2.5; • Operating voltage, V ...... 43.2-52.8; • Insulation resistance between current-carrying elements and case: - in normal climatic conditions ...... not less than 100 MOhm; - in conditions of high humidity ...... not less than 10 MOhm; - at maximum temperature ...... not less than 20 MΩ; • Dielectric strength of insulation between current-carrying elements, current-carrying elements and housing ...... not less than 500 V; • Response time ...... no more than 15 ms; • Release time ...... no more than 8 ms. | 34 | 48 | DIP | 10 pieces. | 0.3 | 1 | neutral | 2500 | — | 500v | Constant | 4 switches | ||||
| 26050 | СНГ | 2 шт |
1,500 грн.
|
EMRV-27B-1 0.2-1s electric machine time relay is designed for switching electrical circuits with certain pre-set time delays and is used in industrial equipment for various purposes, to obtain time delays in industrial automation circuits and relay protection. Assigned resource 10,000 operations, with a time delay less than or equal to 27s; 75h - with time delay over 27s Main technical characteristics: DC supply voltage, V 27 ± 2.7 Supply voltage ripple amplitude, no more than 1% of the supply voltage value Current consumption at temperatures from 15°C to 70°C, A, not more than with the engine on 0.55, after the engine is stopped 0.40 Insulation resistance during the service life, kOhm, not less than 20. | 400 | — | — | 1 PC. | — | — | — | — | — | — | — | — | ||||
|
Relay RPS28 RS4.521.938
#15054
|
27269 | СНГ | 2 шт |
130 грн.
|
Relay RPS-28 RS4.521.938 non-hermetic, polarized, two-position, two-stable, with eight switching elements, designed for switching DC and AC electrical circuits with a frequency of 1500 Hz. Technical characteristics of relay RPS-28 RS4.521.938: The supply current of the windings is constant. Insulation resistance between current-carrying elements, between current-carrying elements and the case, MOhm, not less than: - in normal climatic conditions (windings de-energized) - 200 - at maximum temperature (after holding the windings under operating voltage) - 20 - in conditions of high humidity - 10 Test alternating voltage between current-carrying elements, between current-carrying elements and the case, V: - in normal climatic conditions - 500 - in conditions of high humidity - 300 - at reduced atmospheric pressure - 180 Contact material - Ср999. Resistance of electric contact no more than 1 Ohm. | 150 | 27 | DIP | 10 pieces. | 3 | 4 | polarized | 377 | — | 115v | Constant | 8 shifts | |||
| 27270 | СНГ | 2 шт |
28 грн.
|
RES-55B RS4.569.625-05.02 Dust-splash-proof, reed, two-position, single-stable DC relays are designed for switching DC and AC electrical circuits with a frequency of up to 10 kHz. Technical characteristics of the relay RES-55B RS4.569.625-05.02: • Winding resistance, Ohm ...... 1600-2162; • Operation voltage, V ...... 14.2; • Release voltage, V ...... 1.6; • Operating voltage, V ...... 24.3-29.7; • Insulation resistance between current-carrying elements, current-carrying elements and screen: - in normal climatic conditions not less than ...... 500 MOhm; - in conditions of high humidity not less than ...... 5 MOhm; - at a maximum temperature of at least ...... 20 MΩ; • Dielectric strength of insulation: - between current-carrying elements, current-carrying elements and screen ...... 500 V; - between the terminals of the contacts ...... 200 V; • Electrical capacity: - between contacts 1 and 2 no more ...... 5 pF; - between contacts 2 and 3 no more ...... 2 pF; - between the winding and contact 1 no more ...... 4 pF; - between the winding and contact 3 no more ...... 3 pF; - between the screen and contact 1 no more ...... 5 pF; - between the screen and contact 3 no more ...... 4 pF; - between the screen and the winding no more ...... 85 pF; • Duty cycle at least ...... 5 ms;. | 4.5 | 27 | DIP | 5 pieces. | 0.5 | 1 | neutral | 1880 | — | 127v | Constant | 1 switch | ||||
| 29259 | СНГ | 2 шт |
80 грн.
|
Relay RES10 RS4.529.031-03.02 electromagnetic low-current low-frequency, two-position, monostable, controlled by direct current. Designed for switching electrical circuits of direct and alternating current with a frequency of 50 to 1100 Hz. RES10 relays are produced with pin terminals for surface mounting on a printed circuit board through holes with one normally open or one changeover contact. Provides the possibility of use in both printed and surface mounting. They are used for operation as part of electronic switching control circuits in general-purpose and special-purpose electronic equipment. Switches currents of no more than 2 A at voltages up to 250 V, depending on the switching mode. | 7 | 24...40 | DIP | 24pcs | 2 | 1 | neutral | 630 | — | 250v | Constant | 1 short. | ||||
| 23918 | СНГ | 1 шт |
30 грн.
|
CONNECTING BLOCK WITH MOUNTING PARTS FOR RELAY RP-5. | 22 | — | DIP | 10 pieces. | — | — | — | — | — | — | — | — | ||||
| 28074 | СНГ | 1 шт |
400 грн.
|
Indicating relays of the REU-11 series are designed to signal an emergency condition in the circuit. | 150 | — | Screw | 20pcs | 0.1 | 1 | — | — | — | — | Constant | 2 short circuit | ||||
| 28075 | СНГ | 1 шт |
400 грн.
|
Indicating relays of the REU-11 series are designed to signal an emergency condition in the circuit. | 170 | — | Screw | 20pcs | 0.5 | 1 | — | — | — | — | Constant | 3 short circuit | ||||
| — | — | — |
64 грн.
|
— | Designed for switching electrical circuits of direct and alternating current. Has four changeover contacts. Switches currents from 0.1 to 10 A at voltages from 6 to 220V. Powered by a 27V direct current source. | — | — | — | — | — | — | — | — | — | — | — | — | |||
|
RP21-block-screw(pl)-003
#9880
|
21660 | — | — |
25 грн.
|
— | — | — | — | — | — | — | — | — | — | — | — | — | — | ||
| 21661 | СНГ | — |
65 грн.
|
— | 4 closing. Contact current: 6A Rated voltage: ~220V | 63 | 220 | DIP | 5 pieces. | 6 | 1 | neutral | — | 0.4A | 500v | Variable | 4 short circuit | |||
|
Relay RES15 RS4.591.003
#10335
|
22321 | СНГ | — |
25 грн.
|
— | Relay RES15 RS4.591.003 dust-splash-proof, two-position, single-stable, with one changeover contact, powered by direct current, designed for switching electric circuits of direct and alternating current with a frequency of 50 to 400 Hz. | 3 | 6,3…7,2 | DIP | 36pcs | — | 1 | neutral | 330 | — | — | Constant | 1 switch | ||
| 23323 | СНГ | — |
54 грн.
|
— | Dual bidirectional high voltage MOS relay, DIP6 package. | 0.5 | — | DIP | 100 pieces. | — | — | — | — | — | — | — | — | |||
| 22311 | СНГ | — |
54 грн.
|
— | Dual bidirectional high voltage MOS relay, DIP8 package. | 0.5 | — | DIP | 100 pieces. | — | — | — | — | — | — | — | — | |||
| 23471 | СНГ | — |
54 грн.
|
— | Dual bidirectional high voltage MOS relay, DIP8 package. | 0.5 | — | DIP | 100 pieces. | — | — | — | — | — | — | — | — | |||
|
Relay RES54A HP4.500.012-01
#11619
|
23850 | СНГ | — |
54 грн.
|
— | Technical characteristics of the relay RES-54A HP4.500.012-01: • Winding resistance, Ohm ...... 3400-4600; • Operate current, mA ...... 3.6; • Release current, mA ...... 0.4; • Operating voltage, V ...... 24-32. | 16 | 27 | DIP | 10 pieces. | 0.5 | 1 | neutral | 4000 | — | 100v | AC/DC | 2 switches | ||
|
Relay RES42 RS4.569.152
#11637
|
23867 | СНГ | — |
20 грн.
|
— | • Winding supply current ...... constant; • Winding resistance, Ohm ...... 3400-4600; • Operation voltage, V ...... 14; • Release voltage, V ...... 3; • Operating voltage, V ...... 24-30. | 9.2 | 27 | DIP | 10 pieces. | 0.1 | 1 | neutral | 4000 | — | 30v | Constant | 1 short. | ||
| 24280 | СНГ | — |
25 грн.
|
— | 4.5 | 12 | DIP | 5 pieces. | 0.5 | 1 | neutral | 377 | — | 36v | AC/DC | 1 switch | ||||
| 26009 | СНГ | — |
570 грн.
|
— | UVPM-1-126 0-600sec The microelectronic program-time device is designed for switching electrical circuits with certain pre-set time delays and is used in industrial equipment for various purposes, to obtain time delays in industrial automation circuits and relay protection. Warranty operating time 10000 h. Specifications: TU 25-05.2493-79. | 200 | — | — | 2 pcs. | — | — | — | — | — | — | — | — |