Relay
Filter layout:
|
| MPN | Article | Brand | In stock | Price | Discounts | Quantity | Description | Weight g. | Working voltage, V | Mounting type | Factory packaging | Working current, A | Number of windings | Polarization | Winding resistance, Ohm | Maximum switching voltage | Winding supply current | Contact set |
|---|
|
Thermal relay TRT-115 7A
#13917
|
26096 | СНГ | — |
250 грн.
|
— | Thermal relays TRT-115 7A are designed to protect electrical equipment from overloads. | 380 | — | — | 1 PC. | — | — | — | — | — | — | — | ||||||
| 26889 | SONGLE | — |
12 грн.
|
|
— | Electromagnetic relay 1 normally open group of contacts for 10 A, winding voltage 12 V, winding resistance 400 Ohm. | 8 | 12 | DIP | 100 pieces. | 10 | 1 | neutral | 400 | 250v | Constant | 1 short. | ||||||
| 26890 | CHINA | — |
12 грн.
|
|
— | Electromagnetic relay 1 switching group of contacts for 10 A, winding voltage 12 V, winding resistance 400 Ohm. | 8 | 12 | DIP | 100 pieces. | 10 | 1 | neutral | 400 | 250v | Constant | 1 switch | ||||||
|
Relay RES22 RF4.500.129 12V
#14947
|
27164 | СНГ | — |
40 грн.
|
— | RES-22 RF4.500.129 sheathed, two-position, single-stable, with four switching contacts of a DC relay, designed for switching DC and AC electrical circuits with a frequency of 50 ... 1000 Hz. Technical characteristics of the relay RES-22 RF4.500.129: • Winding resistance, Ohm ...... 157-201; • Operate current, mA ...... 36; • Release current, mA ...... 11; • Operating voltage, V ...... 10.8-13.2; • Insulation resistance between current-carrying elements and case: - in normal climatic conditions ...... not less than 100 MOhm; - in conditions of high humidity ...... not less than 10 MOhm; - at maximum temperature ...... not less than 20 MΩ; • Dielectric strength of insulation between current-carrying elements, current-carrying elements and housing ...... not less than 500 V; • Response time ...... no more than 15 ms; • Release time ...... no more than 8 ms. | 34 | 12 | DIP | 10 pieces. | 0.3 | 1 | neutral | 158 | 500v | Constant | 4 switches | ||||||
|
Relay RES22 RF4.500.131 24V
#14948
|
27163 | СНГ | — |
40 грн.
|
— | RES-22 RF4.500.131 sheathed, two-position, single-stable, with four switching contacts of a DC relay, designed for switching DC and AC electrical circuits with a frequency of 50 ... 1000 Hz. • Winding resistance, Ohm ...... 565-747; • Operate current, mA ...... 19; • Release current, mA ...... 6; • Operating voltage, V ...... 21.6-26.4; • Insulation resistance between current-carrying elements and case: - in normal climatic conditions ...... not less than 100 MOhm; - in conditions of high humidity ...... not less than 10 MOhm; - at maximum temperature ...... not less than 20 MΩ; • Dielectric strength of insulation between current-carrying elements, current-carrying elements and housing ...... not less than 500 V; • Response time ...... no more than 15 ms; • Release time ...... no more than 8 ms. | 34 | 24 | DIP | 10 pieces. | 0.3 | 1 | neutral | 565 | 500v | Constant | 4 switches | ||||||
|
Relay RES22 RF4.500.163 30V
#14949
|
27165 | СНГ | — |
60 грн.
|
— | RES22 RF4.500.163 sheathed, two-position, single-stable, with four changeover contacts DC relay, designed for switching DC and AC electrical circuits with a frequency of 50...1000 Hz. Technical characteristics of the relay RES22 RF4.500.163: • Winding resistance, Ohm ...... 595-805; • Operate current, mA ...... 21; • Release current, mA ...... 3; • Operating voltage, V ...... 27-33; • Insulation resistance between current-carrying elements and case: - in normal climatic conditions ...... not less than 100 MOhm; - in conditions of high humidity ...... not less than 10 MOhm; - at maximum temperature ...... not less than 20 MΩ; • Dielectric strength of insulation between current-carrying elements, current-carrying elements and housing ...... not less than 500 V; • Response time ...... no more than 15 ms; • Release time ...... no more than 8 ms. | 34 | 30 | DIP | 10 pieces. | 0.3 | 1 | neutral | 700 | 500v | Constant | 4 switches | ||||||
| 27166 | СНГ | — |
40 грн.
|
— | RES-22 RF4.523.023-07.01 sheathed, two-position, single-stable, with four switching contacts of the DC relay, designed for switching DC and AC electrical circuits with a frequency of 50 ... 1000 Hz. Technical characteristics of the relay RES-22 RF4.523.023-07.01: • Winding resistance, Ohm ...... 553-780; • Operate current, mA ...... 20; • Release current, mA ...... 4; • Operating voltage, V ...... 21.6-26.4; • Insulation resistance between current-carrying elements and case: - in normal climatic conditions ...... not less than 100 MOhm; - in conditions of high humidity ...... not less than 10 MOhm; - at maximum temperature ...... not less than 20 MΩ; • Dielectric strength of insulation between current-carrying elements, current-carrying elements and housing ...... not less than 500 V; • Response time ...... no more than 15 ms; • Release time ...... no more than 8 ms. | 34 | 24 | DIP | 10 pieces. | 0.3 | 1 | neutral | 565 | 500v | Constant | 4 switches | |||||||
|
Relay RES22 RF4.500.125 60V
#14951
|
27167 | СНГ | — |
40 грн.
|
— | RES-22 RF4.500.125 sheathed, two-position, single-stable, with four switching contacts of a DC relay, designed for switching DC and AC electrical circuits with a frequency of 50 ... 1000 Hz. Technical characteristics of the relay RES22 RF4.500.125: • Winding resistance, Ohm ...... 2380-3080; • Operate current, mA ...... 11; • Release current, mA ...... 2; • Operating voltage, V ...... 54-66; • Insulation resistance between current-carrying elements and case: - in normal climatic conditions ...... not less than 100 MOhm; - in conditions of high humidity ...... not less than 10 MOhm; - at maximum temperature ...... not less than 20 MΩ; • Dielectric strength of insulation between current-carrying elements, current-carrying elements and housing ...... not less than 500 V; • Response time ...... no more than 15 ms; • Release time ...... no more than 8 ms. | 34 | 60 | DIP | 10 pieces. | 0.3 | 1 | neutral | 2700 | 500v | Constant | 4 switches | ||||||
|
Relay RES22 RF4.500.130 48V
#14952
|
27168 | СНГ | — |
40 грн.
|
— | RES-22 RF4.500.130 sheathed, two-position, single-stable, with four switching contacts of a DC relay, designed for switching DC and AC electrical circuits with a frequency of 50 ... 1000 Hz. Technical characteristics of the relay RES-22 RF4.500.130: • Winding resistance, Ohm ...... 2250-2875; • Operate current, mA ...... 10.5; • Release current, mA ...... 2.5; • Operating voltage, V ...... 43.2-52.8; • Insulation resistance between current-carrying elements and case: - in normal climatic conditions ...... not less than 100 MOhm; - in conditions of high humidity ...... not less than 10 MOhm; - at maximum temperature ...... not less than 20 MΩ; • Dielectric strength of insulation between current-carrying elements, current-carrying elements and housing ...... not less than 500 V; • Response time ...... no more than 15 ms; • Release time ...... no more than 8 ms. | 34 | 48 | DIP | 10 pieces. | 0.3 | 1 | neutral | 2500 | 500v | Constant | 4 switches | ||||||
| 27266 | СНГ | — |
60 грн.
|
— | RES-47 RF4.500.407-02.01 sealed, two-position, single-stable DC relay is designed for switching DC and AC electrical circuits with a frequency of 50-2500 Hz. Technical characteristics of the relay RES-47 RF4.500.407-02.01: • Winding resistance, Ohm ...... 585-715; • Operate current, mA ...... 21; • Release current, mA ...... 2.5; • Operating voltage, V ...... 21.5-34; • Insulation resistance between current-carrying elements, current-carrying elements and housing: - in normal climatic conditions ...... not less than 200 MΩ; - in conditions of high humidity ...... not less than 10 MOhm; - at maximum temperature ...... not less than 50 MΩ; • Dielectric strength of insulation under normal climatic conditions: - between current-carrying elements ...... not less than 350 V; - between current-carrying elements and the case ...... not less than 500 V | 8 | 21,5...34 | DIP | 10 pieces. | 2 | 1 | neutral | 640 | 250v | Constant | 2 switches | |||||||
| 27267 | СНГ | — |
30 грн.
|
— | RES-47 RF4.500.407-00.02 sealed, two-position, single-stable DC relay is designed for switching DC and AC electrical circuits with a frequency of 50-2500 Hz. Technical characteristics of the relay RES-47 RF4.500.407-00.02: • Winding resistance, Ohm ...... 585-747 • Operate current, mA ...... 23 • Release current, mA ...... 3 • Operating voltage, V ...... 24-30 • Insulation resistance between current-carrying elements, current-carrying elements and housing: - in normal climatic conditions ...... not less than 200 MΩ - in conditions of high humidity ...... not less than 10 MΩ - at maximum temperature ...... not less than 50 MΩ • Dielectric strength of insulation under normal climatic conditions: - between current-carrying elements ...... not less than 350 V - between current-carrying elements and the case ...... not less than 500 V. | 8 | 24…30 | — | 10 pieces. | 2 | 1 | neutral | 640 | 250v | Constant | 2 switches | |||||||
| 27268 | СНГ | — |
60 грн.
|
— | Relay RES-34 RS4.524.370-00.02 hermetic, two-position, single-stable, with one changeover contact, powered by direct current, designed for switching electric circuits of direct and alternating current. Technical characteristics of the relay RES-34 RS4.524.370-00.01: • Winding supply current ...... constant • Winding resistance, Ohm ...... 3360-5040 • Operate current, mA ...... 8 • Release current, mA ...... 1.2 • Operating current, mA ...... 9.5-10.5 • Insulation resistance between current-carrying elements, between current-carrying elements and case, MOhm, not less than: - in normal climatic conditions (winding de-energized) ...... 200 - at maximum temperature (after holding the winding under operating voltage) ...... 20 - in conditions of high humidity: between contacts, between contacts and housing, between winding and housing, between winding and contacts ...... 10 • Test alternating voltage between current-carrying elements, between current-carrying elements and the case, V: - in normal climatic conditions ...... 500 - in conditions of high humidity ...... 300 - at reduced atmospheric pressure ...... 170. | 9.2 | — | DIP | 10 pieces. | 2 | 1 | neutral | 4200 | 250v | Constant | 1 switch | |||||||
| 27695 | СНГ | — |
25 грн.
|
— | 4.5 | 12 | DIP | 10 pieces. | 0.5 | 1 | neutral | 377 | 36v | AC/DC | 1 switch | ||||||||
| 27699 | СНГ | — |
25 грн.
|
— | 4.5 | 3 | DIP | 10 pieces. | 0.5 | 1 | neutral | 35 | 36v | AC/DC | 1 switch | ||||||||
| 27700 | СНГ | — |
30 грн.
|
— | 4.5 | 5 | DIP | 10 pieces. | 0.5 | 1 | neutral | 67 | 36v | AC/DC | 1 switch | ||||||||
| 27704 | СНГ | — |
25 грн.
|
— | 4.5 | 12 | DIP | 5 pieces. | 0.5 | 1 | neutral | 377 | 36v | AC/DC | 1 switch | ||||||||
|
Relay RMU HP4.523.333
#15705
|
28351 | СНГ | — |
90 грн.
|
— | 75 | 12 | DIP | 1 PC. | 10 | 1 | — | — | 600v | Constant | 1 short. | |||||||
| 28076 | СНГ | — |
400 грн.
|
— | Indicating relays of the REU-11 series are designed to signal an emergency condition in the circuit. | 160 | — | Screw | 20pcs | 0.5 | 1 | — | — | — | Constant | 2 short circuit | |||||||
| 28145 | СНГ | — |
25 грн.
|
— | Relay RES15 RS4.591.004 electromagnetic low-current, two-position, single-stable, DC-powered, with one changeover contact. Designed for switching DC and AC electrical circuits with a frequency of 50 to 400 Hz. RES15 relays are available with pin terminals for surface mounting on a printed circuit board through holes. They provide the possibility of using both in printed circuit and surface mounting. They are used as part of electronic switching control circuits in radio-electronic equipment for general and special purposes. Switches currents from 0.01 to 0.2 A at a voltage of 6 to 150 V. Case type - metal, leaky, dust and moisture protected. | 3 | 16 | — | 36pcs | 0.2 | 1 | neutral | 720 | 150v | — | 1 switch | |||||||
| 28146 | СНГ | — |
80 грн.
|
— | Relay REN18 РХ4.564.510 electromagnetic low-frequency, two-position, one-stable, open, without casing. Designed for switching electrical circuits of direct and alternating current with a frequency of 50 Hz. Relays REN18 are produced with terminals for surface mounting, with one or several contact groups and with a combination of make and changeover contacts. Used for operation as part of electronic switching control circuits in general and special-purpose equipment. Switch currents up to 5.0 A at voltages up to 250 V, depending on the mode switching. Case type - open, without casing. | 230 | 110 | DIP | 1 PC. | 5 | 1 | neutral | 10000 | 250v | Constant | 2 switches | |||||||
|
Relay F3AA024E-HA (24VDC)
#16281
|
28529 | FUJITSU | — |
40 грн.
|
|
— | 5A 250VAC/30VDC, 2880 Ohm, 20.3x7x15mm. | 4 | 24 | DIP | 2500pcs | 5 | 1 | neutral | 2880 | 250v | Constant | 1 short. | |||||
|
Relay HF33F/024-HST (24VDC)
#16282
|
28530 | HONGFA RELAY | — |
45 грн.
|
|
— | 5A 250VAC, 1280 Ohm, 20.5x15.3x10.2mm. | 6 | 24 | DIP | 100 pieces. | 5 | 1 | neutral | 1280 | 250v | Constant | 1 short. | |||||
| 28861 | TIANBO | — |
25 грн.
|
|
— | 9.2 | 5 | DIP | 100 pieces. | 7 | 1 | neutral | 69 | 250v | Constant | 1 switch | |||||||
| 28863 | TIANBO | — |
25 грн.
|
|
— | 9.2 | 12 | DIP | 100 pieces. | 7 | 1 | neutral | 400 | 250v | Constant | 1 switch | |||||||
|
Relay TRG1 D-12VDC-S-Z (12V)
#16653
|
28892 | TIANBO | — |
46 грн.
|
|
— | 6 | 12 | DIP | 500pcs | 5 | 1 | neutral | 320 | 250v | Constant | 1 switch | ||||||
| 28894 | TIANBO | — |
25 грн.
|
|
— | 3A 120VAC/24VDC; 1A 250VAC. | 3.7 | 12 | DIP | 500pcs | 3 | 1 | neutral | 320 | 250v | Constant | 1 switch | ||||||
|
Relay TRA2 L-24VDC-SZ
#16657
|
28896 | TIANBO | — |
80 грн.
|
|
— | 14 | 24 | DIP | 30pcs | 16 | 1 | neutral | 1050 | 250v | Constant | 1 switch | ||||||
|
Relay HJR1-2C-L-24V (24V)
#16658
|
28897 | TIANBO | — |
65 грн.
|
|
— | 5 | 24 | DIP | 500pcs | 1 | 1 | neutral | 3840 | 240v | Constant | 2 switches | ||||||
|
Relay TRV4-L-24V-Z-F (24V)
#16660
|
28899 | TIANBO | — |
85 грн.
|
|
— | 33 | 24 | DIP | 20pcs | 30 | 1 | neutral | 360 | 500v | Constant | 1 switch | ||||||
|
Реле HFD31/5
#16799
|
29046 | HONGFA RELAY | — |
60 грн.
|
|
— | 1.5 | 5 | DIP | 50pcs | 0.5 | 1 | polarized | 78 | 250v | Constant | 2 switches |