Specifications:


Temperature measurement and control range: -50 ~ +110 °C

Measurement accuracy:

- 0.1 ° C - in the aisles from -9.9 to +99.9 ° C

- 1 °C within -50 to -10 and +100 to +110

Control Accuracy:

- 0.1 °C - within -9.9 to +99.9 °C

- 1 °C within -50 to -10 and +100 to +110 °C

Hysteresis: 0.1 to 15 °C

Hysteresis accuracy: 0.1 °C

Refresh rate: 0.5 seconds.

Circuit supply voltage: 12V DC (DC12V).

Power consumption: static current: 35mA; current with relay closed: 65mA

Thermistor: NTC (10K+-0.5%).

The length of the sensor extension is 50 cm.

Output: 1 channel relay output, power=10A

Humidity 20%-85%

Size: 48*40*14mm.


product scope:

Domestic and industrial heating systems, systems

air conditioning, incubators, greenhouses, freezing or cooling

installations, drying cabinets, water heating systems, temperature measurement

engine with the ability to turn on the radiator fan, the temperature at

street, showroom, etc.

Description of the device:
3 control buttons: set, +, - .
set - selects the installation mode and parameter settings
+ and - change the value of the setting and parameters

In C (cooling) mode, it works as follows: while the temperature is below the setpoint, the relay contacts are open, when the set temperature is reached, the relay contacts close and remain in this position until the temperature drops by the value of the set hysteresis (by default, 2ºС).
In H (heating) mode, it works the other way around

If you press the "SET" button, then using the "+" and "-" buttons you can set the temperature for switching on the relay (if the current temperature is LOWER than this value, then the contacts of the power terminals are closed.)
The thermostat must be paired with a heater or cooler.

To set the control temperature, press the SET button, then use the "+" or "-" buttons to set a new temperature, and press the SET button again.

To enter the programming mode, hold down the SET button for 5 seconds, then use the "+" or "-" buttons to select a menu item from the list below. To save the settings, press and hold the SET button, or do not press any buttons for 10 seconds. To return to the default settings, press and hold the "+" button.

Average customer rating:(1)

0
0
0
0
0
1
no rate
  • Хороша річ.
    ByБагрій ДенисNovember 15, 2019 23:30

    Проста у користуванні та багатофункціональна, є налашутвання гістарезісу(підтримання температури у всановленому діапазоні), та багато інших функцій. Низька ціна.

Read all 1 review on Thermostat -50 ~ +110 °C Thermostat XH-W1209 Programmable 12V

Discount− 0 грн.
Affiliate discount− 0 грн.
Total0 грн.

Your cart is empty.